Honeywell BW Ultra 5 (CO2 IR / LEL / O2 / H2S / CO) Gas detector
COD: X1W1H1M1-32
DESCRIPTION
Honeywell BW Ultra Multi Gas Detector
The Honeywell BW Ultra gas detector is a portable monitor with an integrated pump, capable of detecting up to five gases. Available sensors include VOC, LEL, CO, H2S, O2 CO2, SO2, NH3, H2, Cl2, NO2, HCN and NO.
Ultra was designed with limited space monitoring in mind. It is also suitable for inert applications and environmental monitoring, with 3 operating modes. Hole Watch Mode is one of these operational features. This is a graphical feature that quickly determines whether gas levels are reaching their alarm set points.
A new series of sensors is used in this tool. They are of the highest level and quality and will provide extremely accurate readings. The Intelliflash feature allows the wearer to see at a glance if the monitor is compliant. The green LED will show compliance and the reverse Intelliflash LED will flash red and show that the monitor requires assistance.
Gas Standard measuring range Resolution
Oxygen (O2) 0-25% Vol 0.1% vol
Combustible gases (LEL) 0-100% LEL 1% LEL
Combustible gases (IR *) 0-100% LEL (0-5.00% vol) 1% LEL
Hydrogen sulfide (H2S)> 5% Vol. 0.1% vol
Monoxide (CO) 0-100 ppm 1 ppm / 0.1 ppm
of coals
Monoxide (low H2) 0-2000 ppm 1 ppm
of CO-H carbon
Sulfur dioxide (SO2) 0-100 ppm 1 ppm
Hydrogen (H2) 0-2000 ppm 0.1 ppm
Carbon dioxide (CO2) 0-50000 ppm 5 ppm
Ammonia (NH3) 0-100 ppm 100/10 ppm
Volatile organic compound (VOC) 0-1000 ppm 1 ppm
Chlorine (Cl2) 0-20 ppm 1 ppm
Nitrogen dioxide (NO2) 0-50 ppm 0.1 ppm
Hydrocyanic acid (HCN) 0-100 ppm 0.1 ppm
Nitrogen monoxide (NO) 0-200 ppm 1 ppm
SPECIFICATIONS
Measurements: 5.8 x 3.3 x 1.6 inches / 14.8 x 8.5 x 4.0 cm
Weight: 14.5 oz / 411 g (with clip)
operating temperature: from -4 to + 131 ° F / from -20 to + 50 ° C
Humidity: from 5 to 95% relative humidity without condensation
Typical battery life: 18 hours (14 hours with PID or IR sensor) @ -4 ° F / -20 ° C
Pump Draw: Sample up to 75 feet / 22.9 m
Events: 30 alarm events and 10 bump events
Data recording: 45 days based on 8-hour shifts every 15 seconds of registration
User options
• Adjust the STEL period (5-15 minutes at 1 minute intervals)
• Calibration levels
• Calibration interval
• Bump test interval
• Select the measurement of combustible gases: 0-100% LEL
(Lower explosive limit) or natural gas 0-5.0% v / v
• LEL and PID correction factors
• Calibration expiration date (1 to 365 days or set to zero for deactivation)
• Enable / disable individual sensor
• Snap alarms
• Hidden mode
• Languages: English, French, German, Portuguese,
Spanish, simplified Chinese and Russian
Certifications and approvals
UL class
Class I, Div 1, Group A, B, C, D
Class I, Zone 0, IIC Group
ATEX: II 1G Ex ia IIC T4 Ga
IECEx: Ex ia IIC T4 Ga
EC: European conformity
warranty
Instrument: 3 years
Sensors: 3 years (2 years NH3, 1 year PID and Cl2)
Battery: 2 years